The central sensing unit of HS3351 series adopts the world leading pressure/differential pressure transmitter technology and packaging technology, the sensor is located at the top of the metal body, far from the medium contact surface, to achieve mechanical isolation and thermal isolation. Glass sintered sensor leads achieve high-strength electrical insulation with metal matrix, which improves the flexibility of electronic circuits and the ability to withstand transient voltage protection. The accuracy of platinum grade is (+0.05%) and the maximum one-way overvoltage is 25 MPa. Excellent static pressure performance, the optimal static pressure error can be controlled within (+0.05%/10MPa), the temperature effect is very small, and the optimal static pressure error can be controlled within (+0.04%/10K).

In the circuit design, the microprocessor is used as the core and the advanced digital isolation technology is used to assist the modular design, so that the instrument has a very high anti-interference and stability. Hart protocol is used to communicate, which can be operated remotely by Hart operator or computer equipped with Hart software. The configuration of measurement information can be completed. At the same time, digital compensation technology is adopted. The transmitter is compensated by built-in temperature sensor, which improves the measurement accuracy, reduces the temperature drift, and has the characteristics of good long-term stability and high reliability. The most humanized design of infrared wireless settings, one-button zero-clearing function, to meet the requirements of safe operation in dangerous situations, is very convenient for quick menu operation, and can complete all parameter settings, improve the performance of the transmitter in an all-round way.

Advantages

◇Advanced monocrystalline silicon pressure sensor technology and packaging technology, elaborately developed a world-leading technology of ultra-high performance pressure, differential pressure transmitter;

Microprocessor as the core and assisted with the modular design of advanced digital isolation technology, the instrument has high anti-interference and stability.

High Precision Achieved by 24-bit ADC with Powerful Performance

Innovative Double Compensation Technology, Real 0.075 High Precision

Functional parameters

Range

In the upper and lower limits of the range, you can adjust it arbitrarily. It is recommended to select the range code with the lowest range ratio to   optimize the performance.

Zero Setting

Zeros and ranges can be adjusted to any value within the range of measurement in the meter as long as the scale range is greater than or   equal to the minimum range.

Effect   of Installation Position

The change of installation position perpendicular to the diaphragm side will not cause zero drift effect. If the installation position and the diaphragm side change more than 90 degrees, the zero drift effect will occur within the range of < 0.4kPa. It can be corrected by adjusting   the zero adjustment without range effect.

Output

Two-wire system 4-20 mA, in accordance with NAMIR NE43 specification, superimposed digital signal (Hart protocol) can choose linear or square root output.

Output signal limit

Imin=3.9mAImax=21.0mA

Fault warning

If the sensor or circuit fails, the automatic diagnosis function automatically outputs 3.9 or 21.0 mA (user   preset)

Alarm current

Underreporting mode (minimum): 3.9mA

Overreporting Model (Maximum)

21mA

Default setting of alarm current

Overreporting   Model

Response   time

The damp constant of the amplifier is 0.1s, and the time constant of the sensor is 0.1-1.6s, depending on the range and range ratio.

The additional adjustable time constant is 0-100s.

Preheating time

<15s

Performance parameter

Measuring medium: Gas, steam, liquid

Imprecision:±0.05%,±0.075%,±0.1%Including linearity, backlash and repeatability from zero

Stability: ±0.1%/3 years

Environmental Temperature Effect:≤±0.04%URL/10

Static Pressure Effect:±0.05%/10MPa

Power Supply: 1036VDC24VDC recommended

Power Effect:±0.001%/10V(1036VDC), negligible

Reference Accuracy of Adjustment Range: ±(0.075×TD)%, if TD>10(TD=Maximum range/Adjustment range)

Square Root Output Accuracy: 1.5 Linear Reference Accuracy

Environmental Temperature: -40 ~85

Measuring Medium Temperature: -40~120

Storage Temperature: -40~105

Display: LCDOLED

Display Module Temperature: -20~70℃(LCD, -40~80℃(OLED

Overload and static pressure


Range

Unilateral overload (negative end)

Unilateral overload (front end)

Bilateral static pressure

A

1KPa

1MPa

1MPa

16MPa

B

6KPa

2MPa

2MPa

16MPa

C

40KPa

3MPa

3MPa

25MPa

D

400KPa

10MPa

10MPa

25MPa

E

4MPa

10MPa

10MPa

25MPa

 Electromagnetic compatibility (EMC)

ARadio Frequency Radiation Test

Test   field strength

frequency   range

EUT placement

Polarization   direction

detection result

Product number

24283

24281

24282

3V/m

 

80MHz-

1GHz

Upright

Horizontal polarization

Sample memory data remain unchanged

Sample memory data remain unchanged

Sample memory data remain unchanged

Vertical polarization

Sample memory data remain unchanged

Sample memory data remain unchanged

Sample memory data remain unchanged

BPower frequency magnetic field immunity test

 

Magnetic   field intensity

Test result

Product number

24283

24281

24282

400A/mXYZ

Sample   memory data remain unchanged

Sample   memory data remain unchanged

Sample   memory data remain unchanged

Physical parameters


Measuring membrane box: Stainless steel 316L

Diaphragm: stainless steel 316L, Harrington alloy C

Process flange: stainless steel 304, 316L

Nuts and bolts: galvanized carbon steel, stainless steel

Filling fluid: silicone oil, fluorine oil, high temperature silicone oil, etc.

Sealing Ring: Nitrile Butadiene Rubber, Fluorine Rubber, Polytetrafluoroethylene

Transmitter case: aluminium alloy, sprayed epoxy resin

Shell Seal Ring: Nitrile Butadiene Rubber

Nameplate: stainless steel 304

Weight: 2.6kg (no: mounting bracket, process connection)

Shell protection level: IP67

Explosion-proof grade: ExdCT6, ExiaCT6

Installation

Power Supply and Load Conditions

Power: 24VR≤(Us-10V)/ImaxΩ, Imax=21mA

Maximum supply voltage: 36VDC

Minimum supply voltage: 10VDC

Digital communication load range: 250600Ω

Process connection

NPT1/4 and M10 or UNF7/16 internal threads on both ends of process connection flange.

Assembly decomposition diagram of typical products

无标题


01

Rear cover

02

End cap seal ring

03

Connection terminal

04

Punching capacitor

05

housing

06

 Label

07

Anti-interface board

08

Circuit header

09

Display end cover

10

Exhaust Drainage Valve

11

Splint

12

M8 screw

13

Sensor

14

Shell Seal Ring

15

Sensor Seal Ring

16

Shell locking top wire

17

M8 Nut

18

T-joint (selection)

19

Welded pipe   joints (selection)

20

Waist Flange (Selection)

21

Integrated Three Valve Set   (Selection)

Range and scope

Range code

Range(KPa)

Scope(KPa)

Accuracy/stability

A

-11

0.11

 

 

Range(+0.075%F.S)

Maximum annual error is range (+0.1%).

B

-66

16

C

-4040

640

D

-100400

40400

E

-1004000

4004000

Outline size

HS3351DP


HS3351DP Selection Guide

Code

Type

DP

Intelligent differential pressure transmitter


Code

Differential pressure rangeKPa

A

0.11

B

1 6

C

640

D

40400

E

4004000


Code

Output signal

E

420mA

S

420mA+Hart

J

Square root 420mA


Code

Display

M1

LCD

M2

OLEDLow temperature resistance -40)


Code

Pressure guiding method

C0

NPT1/4 Pressure Drainage Joint   and Back Welded Pressure Drainage Pipe Φ14

C1

NPT1/2 Threaded waist flange in   tapered tube

C2

T-shaped   external threaded joint M20*1.5

C3

Integrated three-valve group


Code

Structural material

Flange structure

Drainage/exhaust

Diaphragm

21

304 Stainless   steel

304 Stainless   steel

316L Stainless   steel

22

316 Stainless   steel

316 Stainless   steel

316L Stainless   steel

23

316 Stainless   steel

316 Stainless   steel

Hastelloy C

24

316 Stainless   steel

316 Stainless   steel

Monel alloy

25

316 Stainless   steel

316 Stainless   steel

Tantalum

26

Hastelloy C

Hastelloy C

Hastelloy C

27

Hastelloy C

Hastelloy C

Tantalum

28

Monel alloy

Monel alloy

Monel alloy


Code

Relief valve

X0

Exhaust valve

X1

Drain valve


Code

Mounting bracket

B0

No mounting bracket

B1

Pipe bending bracket

B2

Plate-mounted Bending Bracket

B3

Pipe mounted flat bracket


Code

Hazardous Places Certification   (General Type Not Filled in)

E0

No explosion proof

E1

Flameproof type ExdⅡCT6

E2

Intrinsically safe ExiaⅡCT6


Code

Electrical connection

D1

M20*1.5 Standard

D2

User specified

DP

A

E

M1

C1

21

X0

B1

E1

D1